Instructional Videos from Pentair Water University: Fleck 5600 & 2510 Valves
Fleck 5600
Fleck 5600 Control Valve Tear Down: https://youtu.be/BeD7IdE0FB8
Uses:
- Troubleshooting parts on the 5600 mechanical and SXT valves.
 - Determining what color and size replacement parts you need for your specific valve type.
 - Determining where replacement parts go.
 - This video covers replacement of seals and spacers and piston, plus the examination and/or replacement of the brine valve (softeners only), the injector assembly (softeners only), and drain line flow control. The instructional video is done with a mechanical meter softener valve (Econominder) but can be generalized to any 5600 control.
 
Special Notes: Seals and spacer replacement using the stuffer tool begins at 7:00 minutes. The job is often done without the use of the stuffer tool.
Fleck 5600 Air in Brine System: https://youtu.be/c923S1j-Zbc
Use to check for air entering a brine system and check for damaged fittings or hose:
- When there is low to no salt usage by softener,
 - The service water is “hard”,
 - There are visible leaks, or
 - Experiencing water hammering, or hydraulic shock, during regeneration
 - This video covers the connections and tubing in the brine draw system from the valve body to the air check in the brine tank. A Fleck 5810 is used in the demo, but all other Fleck controls work exactly the same.
 
Fleck 5600 Brine Valve Repair and Replacement: https://youtu.be/MiJktBgvi38
Use when:
- There is salty service water,
 - The brine tank is overfilling, or
 - There is excessive salt use
 - This video covers inspection and/or replacement of the brine valve. The 5600 mechanical meter softener valve (Econominder) is used in the demo, but it can be generalized to other Fleck controls.
 
Fleck 5600 Injector Repairs: https://youtu.be/Rq3JR0FNkwE
Clean or replace a clogged injector or screen when:
- The brine tank is overfilling,
 - No soft water to home, or
 - There is salty service water
 
Fleck 5600 Drain Hose: https://youtu.be/M2vt85Bb6Yk
Diagnose and clear an obstructed drain hose when:
- The pressure drops in the home,
 - There is salty service water, or
 - There is slow to no drain flow during service regeneration
 
Fleck 5600 Meter Repairs: https://youtu.be/NWjjC__66xc
Meter not registering flow when there is:
- No regeneration
 - No salt use
 - No capacity decline on the control, or
 - No flow indicator on the display
 
Depressurize Fleck 5600 Valve: https://youtu.be/iYHXHVD5ik8
Depressurize a system before completing any service work.
Set Time on Fleck 5600 Controller: https://youtu.be/NTp-Qm4j9y0
Use when the:
- Regeneration cycle occurs at the wrong time
 - Display shows the wrong time
 
____________________________________________________________________________
Fleck 2510
Fleck 2510 Control Valve Tear Down: https://youtu.be/9kGhqrbt_R0
Uses:
- Troubleshooting parts on the 5600 mechanical and SXT valves
 - Determining what color and size replacement parts you need for your specific valve type
 - Determining where replacement parts go
 
Seals and spacers replacement begins at 9:20 on the video.
Fleck 2510 Air in Brine System: https://youtu.be/wY9oSSCD9E4
Use when air might be the brine system due to:
- Low to no salt usage
 - Hard service water
 - Visible leaks, or
 - Water hammering during a regeneration
 
Fleck 2510 Brine Valve Repair and Replacement: https://youtu.be/x3Zp_OR5f6M
Use when:
- There is salty service water,
 - The brine tank is overfilling, or
 - There is excessive salt use
 
Fleck 2510 Injector Repair: https://youtu.be/Cbfp2cEKx_c
Clean or replace a clogged injector or screen when:
- Water overfills the brine tank
 - There is no soft water, or
 - There is salty service water
 
Fleck 2510 Drain Hose: https://youtu.be/1B6Gj2xHrkw
Diagnose and clear an obstructed drain hose when:
- Pressure drops in the home
 - Service water is salty, or
 - There is slow to no drain flow during regeneration
 
Fleck 2510 Meter Repairs: https://youtu.be/rD-2acNxW4Y
Use when there is:
- No regeneration
 - No salt use
 - No capacity decline on the control, or
 - No flow indicator on the display
 
Depressurize Fleck 2510 System: https://youtu.be/9I8UYps_tSA
Depressurize a system before completing any service work.
			
	
			
 
			
			